Elevator devices

Elevator load control device SenS Lift™

The next generation elevator load control device SenS Lift measures the signals from the load cells and is used to control the elevator’s load.

The device has between 1 and 6 independent measuring channels for full-bridge type load cells. Temperature compensation and digital signal processing are performed for every channel.

 

Sens Lift extends the functionality of the elevator load control device:

1. Simplified installation

  • Elevator load capacity is set at the site (standard load or user value).
  • Calibration is performed by saving empty car weight and for additional percision known weight (for example, installation personnel weight).

2. Simplified controls

  • The keyboard allows you to choose the data display mode, enter load capacity, calibrations and other data.
  • User-friendly English interface (other languages are optional).

 

3. Universal device for working with different load cells

The device can be used with various types of load cells:
  • floor (LA series) 
  • wire rope (LB series)
  • machine bed frame (LD series).
 
4. Extended relay output functionality
The device generates dry contact relay output signals:
 15/20 kg (helps to detect a child’s weight)
 50% of net rated load (emergency evacuation)
 90% of net rated load (optimization of the elevator)
 110% of net rated load.
Relay output "15/20 kg" uses a polarized relay. In case of power outage this allows emergency lightning to go on when passengers are trapped inside.
 
5. Versatile power supply
The device power supply:
  •  DC 24V
  •  AC 110V, 50-60 Hz
  •  AC 220V, 50 Hz.
Power consumption is less than 5 watts.
 
 
SENS LIFT WITH 4 FLOOR LOAD CELLS

Sens Lift with floor load cells is used on elevators with fixed floor and the following load capacities, kg:
  •  400
  •  630
  •  1000
  •  Value, set by user but not more than Net rated load (1,000 kg).

 

Specifications for SenS Lift with load cells under the floor

Parameters

Value

Limit

Gross rated load, kg

2,300

max

Net rated load, kg

1,000

max

Minimum load, kg

20

 

Total error, %

± 1

of net rated load

Power consumption, W

5

max

Power

AC 220V/50Hz
AC 110V/50-60Hz
DC 24V
±10%/±1Hz
±10%/±1Hz
±15%
Safe overload, % Net rated load 150 min

Working temperature, ˚С

from -20 to +50

range

Ingress Protection (according to EN 60529):
 
          load cell PVT-L
 
          SenS Lift device
 
          connecting box

 

IP67

IP20

IP54

 

 

 

 

Average full service life, years

25

min

 

Elements of SenS Lift with 4 floor load cells

Item

Dimensions, mm

Weight,

kg

Length

Width

Height

Load cell PVT-L

200

80

50

0,72

SenS Lift device

135

135

32

0,30

Connecting box

70

26

24

0,05

Connection cable

5000

Ø8

0,32

 
SENS LIFT WITH WIRE ROPE LOAD CELL

Depending on the elevator’s load capacity, its design features and the number of wire ropes, SenS Lift with wire rope load cells can be calibrated to different load capacity.
 
 
 

Specifications of a single wire rope load cell

Parameters

Value

Limit

Notes

Operating load (OL), kg

1,000

max

 

Total error, % OL

1,0

max

 

Sensitivity, mV/V

2

-0,5/+0,2

 

Wire rope diameter, mm

8, 10, 12    

Excitation, V

from 2,5 to 12

range

 

Input / output resistance, Ohm

400

± 4,0

 

Insulation resistance, MOhm

1000

min

DC 100В

Ingress Protection (according to EN 60529)

IP67

not worse than

 

Working temperature, °С

from - 35 to +70

range

 

Temperature coefficient °С, % OL

0,03

 

 

Safe overload, % OL

150

min

 

Ultimate overload, % OL

200

min

 

Net rated load of SenS Lift with wire rope load cells depends on the number of load cells.

 

Elements of SenS Lift with rope load cells

Item

Dimensions, mm

Weight,

kg

Length

Width

Height

Rope load cel

126

22

60

0,30

SenS Lift device

135

135

32

0,30

Connecting box

70

26

24

0,05

Connection cable

5000

Ø8

0,32

 

 

SENS LIFT WITH MACHINE BED FRAME LOAD CELLS

SenS Lift LD series with machine bed frame load cells has the following characteristics in addition to the functionality of SenS Lift, LA and LB series:
 
1. Analog output to control the frequency drive, whose signal is proportional to the net weight. The analog output is galvanically isolated and can be configured as current or voltage output with different ranges.
2. In the formation of the control logic, a galvanically isolated logic input can be used, the input signal levels are from 24 V DC to 220 V AC.
 
 

Specifications of SenS Lift with machine bed frame load cells

Parameters

Value

Limit

Gross rated load, kg

4,000

max

Net rated load, kg

2,000

max

Minimum load, kg

15

max

Total error, %

± 0,5

of net rated load

Safe overload, % Net rated load

150

min

Ultimate overload, % Net rated load

300

min

Conversion cycle time, ms

100

min

Number of load cells

2

 

Outputs:

 

 

relay

4

AC 220V - 0,1A/
DC 30V - 3A

analog

1

current / voltage

Logical output, V

from 24 DC to 110 AC

 

Ingress Protection (according to EN 60529):
 
load cells
 
SenS Lift device

 

IP54

IP20

 

 

 

Working temperature, °С

from - 20 to +50

range

Power supply

24V DC
 
110V, 60Hz
 
220V, 50Hz

± 20 %

± 15 %

± 15 %

Power consumption, W

5

max

Service life, years

25

min

 


Elements of SenS Lift with machine bed frame load cells

Item

Dimensions, mm

Weight,

kg

 

Length

Width

Height

Machine bed frame load cell

Ø 100

25

0,10

SenS Lift device

135

135

32

0,30

Connecting box

52

26

24

0,05

Connection cable

5000

Ø8

0,32