Elevator devices

Elevator load control device УПС-3

UPS-3 load control device is used for controlling the load of the elevator car.

UPS-3 has a well-deserved reputation on the market of Ukraine and CIS countries. In 2013, VEDA Group of Companies produced over 5,000 devices for companies such as:

  • Karacharovsk Mechanical Plant OJSC
  • Mogilevliftmash OJSC
  • other elevator manufacturers.

Areas of use

UPS-3 measures the signals from the load cells and generates three dry contact relay outputs:

  • 20 kg load
  • 90% of Operating load
  • 110% of Operating load (or 100%+75 kg)

and displaying them on the device’s front panel.

 

UPS-3 is made in the following configurations:

  • with 4 floor load cells
  • with 3-6 wire rope load cells.

 

 

UPS-3 with 4 floor sensor load cells

UPS-3 with floor sensor load cells is used on elevators with stationary floor and the following load capacity, kg:

  • 400
  • 630
  • 1,000.

 

Specifications of UPS-3 with 4 floor sensor load cells

Parameter

Value

Limit

Gross rated load, kg

2,300

max

Operating load (OL), kg

1,000

max

Minimum load, kg

20

 

Total error, % OL

± 1

 

Conversion cycle time, s

2

max

Power consumption, W

10

max

Maximum permissible error, % of net rated load

0.5

max

Ultimate  overload for one load cell, % OL

300

min

Power, V/Hz

~220/50

±10%/±1Hz

Working temperature, ˚С

from -20 to +50

range

Level of cage protection under GOST 14254-96:

ПВТ-Л load cell

ВП-Л device

Connection box

 

IP67

IP20

IP54

 

 

 

 

Average full service life, years

25

min

 

Elements of UPS-3 with 4 floor sensor load cells

Item

Dimensions, mm

Weight, kg

Length

Width

Height

ПВТ-Л load cell

200

80

50

0.72

ВП-Л device

135

115

32

0.35

Connection box

52

26

24

0.05

Connection cable

5,000

Ø8

0.32

 

UPS-3 with wire rope load cells

 

Depending on the elevator’s load capacity, its design features and the number of wire ropes, the UPS-3 with rope load cells can be calibrated to various load capacities.

Specifications of a single wire rope load cell

Parameter

Value

Limit

Notes

Operating load (OL), kg

1,000

max

 

Precision type

1.0

 

 

Total error, % OL

±1

max

 

Sensitivity, mV/V

2

-0.5/+0.2

 

Excitation, V

from 2.5 to 12

range

 

Input / output resistance, Ohm

400

± 4.0

 

Insulation resistance, MOhm

1,000

min

DC 100В

Ingress Protection (according to EN 60529)

IP67

not worse than

 

Working temperature, °С

from -35 to +70

range

 

Temperature coefficient, % OL

0.03

 

 

Safe overload, % OL

150

min

 

Ultimate overload, % OL

200

min

 

Operating load of УПС-3 with rope load cells depends on the number of cells used.

 

Elements of UPS-3 with wire rope load cells

Item

Dimensions, mm

Weight, kg

Length

Width

Height

Wire rope load cell

126

22

60

0.30

ВП-Л device

135

115

32

0.35

Connection box

52

26

24

0.05

Connection cable

5,000

Ø8

0.32