Elevator devices

SenS Lift with commutation protocol CAN open

Next generation of SenS Lift with commutation protocol CAN open is designed for usage in elevator automatisation system, measures the signals from the load cells and is used to control the elevator’s load.

Application

Elevators of various types, including passenger, as the alarm of overload. Furthermore, SenS Lift can be used for measuring other parameters of elevator systems by direct or indirect methods.

 

Advantages

1. Simplified installation

  • Elevator load capacity is set at the site (standard load or user value).
  • Calibration is performed by saving empty car weight and for additional percision known weight (for example, installation personnel weight).

2. Simplified controls

  • The keyboard allows you to choose the data display mode, enter load capacity, calibrations and other data.
  • User-friendly English interface (other languages are optional).

 

3. Universal device for working with different load cells

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The device can be used with various types of load cells:
  • floor (LA series) 
  • wire rope (LB series)
  • machine bed frame (LD series).
 
4. Extended relay output functionality
The device generates dry contact relay output signals:
 15/20 kg (helps to detect a child’s weight)
 50% of net rated load (emergency evacuation)
 90% of net rated load (optimization of the elevator)
 110% of net rated load.
Relay output "15/20 kg" uses a polarized relay. In case of power outage this allows emergency lightning to go on when passengers are trapped inside.
 
5. Versatile power supply
The device power supply:
  •  DC 24V
  •  AC 110V, 50-60 Hz
  •  AC 220V, 50 Hz.
Power consumption is less than 5 watts.
 
 

SENS LIFT WITH 4 FLOOR LOAD CELLS

Sens Lift with floor load cells is used on elevators with fixed floor and the following load capacities, kg:
  •  400
  •  630
  •  1000
  •  Value, set by user but not more than Net rated load (1,000 kg).

 

Specifications for SenS Lift with load cells under the floor

Parameters

Value

Limit

Gross rated load, kg

2,300

max

Net rated load, kg

1,000

max

Minimum load, kg

20

 

Total error, %

± 1

of net rated load

Power consumption, W

5

max

Power

AC 220V/50Hz
AC 110V/50-60Hz
DC 24V
±10%/±1Hz
±10%/±1Hz
±15%
Safe overload, % Net rated load 150 min

Working temperature, ˚С

from -20 to +50

range

Ingress Protection (according to EN 60529):
 
          load cell PVT-L
 
          SenS Lift device
 
          connecting box

 

IP67

IP20

IP54

 

 

 

 

Average full service life, years

25

min

 

Elements of SenS Lift with 4 floor load cells

Item

Dimensions, mm

Weight,

kg

Length

Width

Height

Load cell PVT-L

200

80

50

0,72

SenS Lift device

135

135

32

0,30

Connecting box

70

26

24

0,05

Connection cable

5000

Ø8

0,32

 

SENS LIFT WITH WIRE ROPE LOAD CELL


Depending on the elevator’s load capacity, its design features and the number of wire ropes, SenS Lift with wire rope load cells can be calibrated to different load capacity.
 
 
 

Specifications of a single wire rope load cell

Parameters

Value

Limit

Notes

Operating load (OL), kg

1,000

max

 

Total error, % OL

1,0

max

 

Sensitivity, mV/V

2

-0,5/+0,2

 

Wire rope diameter, mm

8, 10, 12    

Excitation, V

from 2,5 to 12

range

 

Input / output resistance, Ohm

400

± 4,0

 

Insulation resistance, MOhm

1000

min

DC 100В

Ingress Protection (according to EN 60529)

IP67

not worse than

 

Working temperature, °С

from - 35 to +70

range

 

Temperature coefficient °С, % OL

0,03

 

 

Safe overload, % OL

150

min

 

Ultimate overload, % OL

200

min

 

Net rated load of SenS Lift with wire rope load cells depends on the number of load cells.

 

Elements of SenS Lift with rope load cells

Item

Dimensions, mm

Weight,

kg

Length

Width

Height

Rope load cel

126

22

60

0,30

SenS Lift device

135

135

32

0,30

Connecting box

70

26

24

0,05

Connection cable

5000

Ø8

0,32